<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-26 16-47-00
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 61 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 6.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 61 kHz 18442 0,5802
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,3 dBr 1,91 dBr 4,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 61 kHz MIN: 11 kHz % above 76 kHz: 0,5802 Acquired: 2025/02/26 16.45.57 Total samples: 18442 Equivalent time: 0:15:22 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 4,4 dBr MIN: 1,3 dBr AVE: 1,91 dBr % above 12,2 dBr: 0,0 Last value: 1,4 dBr (2025/02/26 16.45.56) 16.32 16.34 16.36 16.38 16.40 16.42 16.44 0 2 4 Pm [dBr]